Principle of Safe Use of Seed Mixer Coating Machine

Principle of Safe Use of Seed Mixer Coating Machine

First, preparation before dressing and dressing Technical status inspection Check whether the machine parts are complete, whether the various couplings are tight, whether the moving parts are flexible, whether the operating mechanism is reliable, and whether butter is added to each bearing. 2. Before the liquid medicine mixed with the drug coating test, whether it can continuously and stably spray, whether there is leakage of the drug, or the phenomenon of air leakage, it is suitable for the kind and mixing conditions. According to the ratio of seed and liquid medicine to adjust the amount of liquid medicine, atomization, if necessary, to adjust. 3. Mixing powder and drug before the coating test to observe whether it can continuously stabilize powder supply, seed and mix evenly, according to the ratio of seed and powder to adjust the amount of powder. When the smoother seeds are mixed with powder, they can also be used together with powder and liquid (water) agents. Second, the drug coating technology requirements 1, add liquid drugs must be placed on the filter, to prevent impurities into the liquid medicine tank block drug road. 2. Start mixing the motor, stirring shaft should be rotated in the clockwise direction (from the tail end of the discharge port), mixing machine smooth and quiet sound. 3. Add 20 kilograms of water to the liquid tank, open its outlet valve and return valve, and start the pump motor to determine the correct direction of rotation of the pump. Refer to the steering instructions on the fan casing of the motor (Note: The pump cannot be started without liquid). 4. Turn on the power switch of the control box of the powder electric vibration feeder, and gently rotate the current adjustment knob. The indication value on the current meter should be adjustable within the rated value range. The vibration motor should work normally and smoothly. 5. Check the air compression oil level and start the motor to determine the correct direction of operation. When the working pressure rises to the rated value, open the exhaust valve and adjust the inlet pressure regulator of the atomization device so that the air flow is smooth and the pressure can be within the rated range. Internal adjustment. 6. Infusion lines and intake lines must not leak or leak. 7. After each end, clean the parts with water and let the water out. After six months of general production, the rotating parts of the machine are lubricated and maintained. 8. When mixing medicine, each seed should be cleaned for every other medicine. Third, mixed drug coating operation precautions 1. When operating, strictly follow the technical requirements. 2, liquid medicine barrels should avoid no liquid start, there is liquid before the start, the liquid valve and return valve should be opened. 3. If the dispensing port of the blender is manually fed, the speed of changing the sacks should be faster. Try to shorten the time for inserting the outlet plate to prevent the stirring tank from being blocked. Don't put hands on the chain guard to avoid accidents. 4. When the machine fails, it should be stopped immediately. 5. When working, staff should take necessary anti-virus protection measures to prevent drug poisoning. 6. After the winter shutdown, pay attention to the release of the liquid in the liquid tank to prevent freezing. Fourth, mixed drug coating common faults and exclusion 1. Non-uniformity of the mix of seeds and herbs is not correct. By adjusting the size of the dose and the amount of seed fed to solve. 2 The feed amount is not suitable. By adjusting the amount of feed you can adjust the mix to a better state. 3 The liquid level in the tank is too low. If the liquid level is still not reached by adjustment, check the supply line for clogging and remove the blockage. 2. The discharge port seed is not mixed and the hopper of the tank is not oscillated. The sundries stuck on the hopper, which can be used to toggle the pendulum block or remove debris; the swing shaft bearing or hopper valve does not rotate smoothly and should be lubricated. 2 The height of the leveling tank is not enough. When the powder in the powder medicine case sometimes appears overhead, a small stick can be used to stir the powder medicine several times. 3. During work, the sound of the motor of the blender is abnormal or does not turn. At this time, it is generally blocked in the mixing tank and should be immediately shut down for inspection. The causes are as follows: 1 The discharge from the discharge port is not timely, and the material should be discharged in time. 2 violates the operating procedure. Start the hoist and feeder first, then start the mixer or stop the mixer first, then stop the elevator and feeder. 3 The amount of feeding is too large. 4. During work, the sound of the hoist motor is abnormal or does not turn. At this moment, the inside of the hoist is blocked and should be checked for shutdown immediately. The reasons are: 1) The hoist belt is too loose and slippery. 2 Mixer did not start. 5. When the empty machine starts, the motor sounds abnormal or does not turn. At this time, the electrician should check the current, circuit and motor.

Freeze Dried Papaya Snacks

Freeze Dried Papaya Snacks,Bulk Dried Fruit ,Dry Fruits Gift Pack ,Bulk Fruit

Edible Fungus & Algae Co., Ltd. , http://www.nbmushroom.com