Principle of high frequency electric knife -- electric shock and electric cutting The principle of using a high-frequency electrosurgical unit in the operating room is very similar to these. The high frequency electric knife generates high voltage and high frequency current. The circuit includes a high frequency electric knife, a knife pen, a patient's body and a negative plate. The current flows from the high-frequency electric knife, enters the human body through the lance, and then flows back from the negative plate to the machine. When current flows through the body, it generates huge amounts of heat to overcome the body's tissues. Bipolar coagulation The two legs of the bipolar coagulation dice concentrate the output pole and the loop pole respectively, so the bipolar coagulation can form a loop by itself without the negative plate . Therefore, in bipolar surgery, it is not necessary to use a negative plate. This is a big difference between unipolar and bipolar zui. In bipolar coagulation surgery, the output pole of the high-frequency current and its circuit are in the surgical area. The two legs of the bipolar electrocoagulation force perform two functions of output and circuit respectively, so the current is only on these two feet. The flow between the tissues does not affect other parts of the body. However, the voltage in bipolar coagulation surgery is more than electric cut and electrocoagulation, and its voltage peak can exceed 9000V . Monopolar electrocoagulation In unipolar surgery, the output of the high frequency current is at the surgical wound, ie on the activation electrode. The negative plate is attached to the rest of the body outside the wound, and is generally a place rich in muscle. During the operation, current flows from the knife of the electrosurgical knife and flows out of the negative plate through the body, thus forming a complete high-frequency circuit. Only when a complete high-frequency circuit is formed can there be electrical or electrocoagulation, so in unipolar surgery, we must use a negative plate. The output voltage of the monopole cut is about 6000V , and the output voltage of the monopolar coagulation is about 6000--7000V . From electric cutting to hybrid cutting to electrocoagulation, the voltage gradually increases. Due to its practical efficiency and convenience, unipolar electric coagulation is the common surgical method used by Zui. The difference between electric cutting and electrocoagulation The effect of the final thermal effect of determining a high-frequency current is the waveform of its current and the amount of heat it generates. When we use a continuous high-frequency current waveform, the current generates a large amount of heat and a very high temperature in an instant, which causes the tissue to vaporize and separate the tissue. This is what we often call the " electric cut " effect. When the current waveform of the output is intermittent, the amount of heat generated instantaneously is greatly reduced, and the temperature is relatively low, which is insufficient for the vaporization of the tissue and only the effect of scalding, that is, the effect of " coagulation " . The current waveform of the electric cut is a continuous high frequency waveform, and the electrocoagulation is a pulse type high frequency current waveform, and the mixed current waveform is between the two. The voltage of the electric cutting is low , but the waveform is dense and the energy is high ; The energy of electrocoagulation is low but the output voltage is high ; Effect of different high frequency current waveforms on surgical outcome The high frequency electric knife can output high frequency currents of various waveforms. When the high-frequency current waveform changes, the cutting effect of the current on the tissue also changes. When we use a fixed high-frequency current such as " electric cutting " , the high-frequency electric knife instantaneously generates a large amount of heat, which can vaporize the cells and cut the tissue. When we make the electric knife output a periodic high-frequency current, such as " coagulation " , the waveform of this current generates less heat per unit time, so unlike the effect of cell vaporization, the tissue burns Shows the effect of electrocoagulation. When the high-frequency electric knife outputs a mixed waveform between " electric cutting " and " coagulation " , the thermal effect of the high-frequency current on the human tissue is also between " electric cutting " and " electrocoagulation " . There are three kinds of " hybrid cutting " modes for high-frequency electric knives . From " mixing and cutting 1" to " mixing and cutting 3" , the factors of electric cutting are gradually reduced, the factors of electrocoagulation are gradually increasing, and the high-frequency effect is also from " electric cutting." " Steering " electrocoagulation " .
We are manufacturer of Cloud Indoor Camera in China, if you want to buy Mini Camera ,Cloud Indoor Camera,Solar PTZ CCTV, Solar Security CCTV Camera ,Full HD 1080P 4G Version please contact us.
There is no doubt that solar monitoring has brought great convenience to people. It saves a lot of manpower and material resources without having to stick to the post for 24 hours as before. Not to mention that the current surveillance cameras have the function of motion detection. As long as someone enters a certain range, it will automatically alarm and capture the scene. What is the function of the solar monitoring system? Cloud Indoor Camera,Solar PTZ CCTV, Solar Security CCTV Camera ,Full HD 1080P 4G Version Shenzhen Fuvision Electronics Co., Ltd. , https://www.outdoorsolarcameras.com
1. Solar panel: The solar panel is an important part of the mobile phone software of the solar power generation system, and also a part of the practical value of the mobile phone software of the solar power generation system. Its function is to convert the professional ability of radioactive substances in natural light into electric energy, or send them to storage batteries, or promote load work.
2. Solar controller: The solar controller is used to control the operation of mobile phone software in all systems, and has the functions of overcharge protection and overcharge maintenance for the battery. In areas with large temperature difference, the qualified controller shall also have the function of temperature compensation. In the mobile phone software of the solar road lamp system, there must be light control switch and time control solar road lamp operation.
3. Battery: generally valve controlled maintenance free lead-acid battery. In the mobile phone software of small and medium-sized systems, in cold weather areas, a solar gel battery needs to be configured, which can be used at low temperatures, with high efficiency and is not vulnerable to major damage. Its function is to store the electric energy of the solar panel when the sun shines, and then release it under certain conditions.
4. Variable frequency power supply: split wave type and sine wave type. In order to provide power for 220VAC electrical products, it is necessary to convert the DC stabilized voltage power supply in the solar power generation system software into AC circuit energy, so DC AC variable frequency power supply is required.
Take you to know the high frequency electric knife>