Ceramic Bearings of Dental High Speed Handpiece Kavo Replacement

Ceramic Bearings of Dental High Speed Handpiece Kavo Replacement

Model NO.: AP-122
Medical Device Regulatory Type: Type 2
Medical Devices Ad. Approval No.: Ysyjxz20132550481
3.175*6.35*2.38: Compatible with Kavo
Trademark: SPTA
Transport Package: Cartons
Specification: CE
Origin: China
HS Code: 9018499000
Model NO.: AP-122
Medical Device Regulatory Type: Type 2
Medical Devices Ad. Approval No.: Ysyjxz20132550481
3.175*6.35*2.38: Compatible with Kavo
Trademark: SPTA
Transport Package: Cartons
Specification: CE
Origin: China
HS Code: 9018499000
Ceramic Bearings of Dental High Speed Handpiece Kavo Replacement

compatible with KAVO
Size:
Bore(d):3.175mm (0.125inch)
O.D.(D):6.35mm (0.250inch)
Width-(B):2.38mm/2.78mm (0.1094inch) Step bearing

Features: With Groove
This class bearings for dental handpiece bearingsinternal and external rings adopts refined stainless steel (9Cr18Mo) materialsball using refining stainless steel (AISI440C) or non-metallic superhard ceramics (Si3N4) materialit has good abrasion resistanceKeep wearing USES high strengthlow grinding resistance and self-lubricating etc performance of polyimide materials or 80 ~ 120 teams phenolic clip cloth bakelite materialsbearing in 200 ~ 250Kpa air pressurethe speed can reach  350000 ~450000rPm. In normal conditionsbearing the working life for more than six months.
High-speed handpiece bearingsmanufacturing precision conforms to the national standard of GB/T307.1-2005 P4 level requirementcan apply to different type dentist at home and abroad handpieces. The high-speed handpiece bearingscan be used for high-speed grinding machine.

Introduction: 
1.It is best that the interference fit between bearing bore and turbine shaft is under 0.5um~1.5um. When putting burbine shaft into bearing bore,the pressure should be forced on the face of inner ring to avoide the damage of rollway and balls 
2.After fitting the bearing into tubine shaft they should be clear and instilled special lubricant.(Ethanol must not be used ) 
3.After high steam sterilized the Dental High Speed Handpiece should be jetted some lubricant into the air inlet before used and so that bearing could be used longer time. 
4.To keep operating stability,the proload spring stress of bearing should be controlled under 1.2±0.2N

Ceramic Bearings of Dental High Speed Handpiece Kavo Replacement
  Ceramic Bearings of Dental High Speed Handpiece Kavo Replacement

compatible with KAVO
Size:
Bore(d):3.175mm (0.125inch)
O.D.(D):6.35mm (0.250inch)
Width-(B):2.38mm/2.78mm (0.1094inch) Step bearing

Features: With Groove
This class bearings for dental handpiece bearingsinternal and external rings adopts refined stainless steel (9Cr18Mo) materialsball using refining stainless steel (AISI440C) or non-metallic superhard ceramics (Si3N4) materialit has good abrasion resistanceKeep wearing USES high strengthlow grinding resistance and self-lubricating etc performance of polyimide materials or 80 ~ 120 teams phenolic clip cloth bakelite materialsbearing in 200 ~ 250Kpa air pressurethe speed can reach  350000 ~450000rPm. In normal conditionsbearing the working life for more than six months.
High-speed handpiece bearingsmanufacturing precision conforms to the national standard of GB/T307.1-2005 P4 level requirementcan apply to different type dentist at home and abroad handpieces. The high-speed handpiece bearingscan be used for high-speed grinding machine.

Introduction: 
1.It is best that the interference fit between bearing bore and turbine shaft is under 0.5um~1.5um. When putting burbine shaft into bearing bore,the pressure should be forced on the face of inner ring to avoide the damage of rollway and balls 
2.After fitting the bearing into tubine shaft they should be clear and instilled special lubricant.(Ethanol must not be used ) 
3.After high steam sterilized the Dental High Speed Handpiece should be jetted some lubricant into the air inlet before used and so that bearing could be used longer time. 
4.To keep operating stability,the proload spring stress of bearing should be controlled under 1.2±0.2N

Ceramic Bearings of Dental High Speed Handpiece Kavo Replacement
Â